Rat soluble interleukin-2 receptor (sIL-2R) ELISA kit

Rat soluble interleukin-2 receptor (sIL-2R) ELISA kit

(Used in serum, plasma, cell culture supernatant and other biological fluids)

principle

This experiment uses the double antibody sandwich ABC-ELISA method. The anti-rat sIL-2R monoclonal antibody was coated on the enzyme plate. The sIL-2R in the standard and the sample was combined with the monoclonal antibody. Biotinylated anti-rat sIL-2R was added to form an immune complex and connected to the plate On the top, the horseradish peroxidase-labeled Streptavidin is combined with biotin, the substrate working solution is added, the blue is added, and finally the stop solution sulfuric acid is added. The OD value is measured at 450nm. Draw a standard curve to find the concentration of sIL-2R in the specimen.

Kit composition (stored at 2-8 ° C)

Coated Wells

96 wells

Enzyme Conjugate

12ml

10 × Sample Buffer

12ml

20 × concentrated washing solution (Wash Buffer)

50ml

Standards (Standards): 120ng / bottle

2 bottles

Substrate working solution (TMB Solution)

12ml

The first antibody working solution (Biotinylated Antibody)

12ml

Stop Solution (Stop Solution)

12ml

Prepare reagents and collect blood samples

1. Collect specimens: serum, plasma (EDTA, citrate, heparin anticoagulation), cell culture supernatant, tissue homogenate, etc. as soon as possible, stored at 2-8 ℃ for 48 hours; longer time must be frozen (-20 ℃ Or -70 ℃), avoid repeated freezing and thawing. Serum and plasma were diluted 1:10 (take 20ul, add sample dilution 180ul, and dilute 10 times). The cell culture supernatant can be directly tested without dilution.

2. Standard solution preparation: Add 6ml of distilled water to mix well before use to make a 20ng / ml solution. Set 8 standard tubes, add 900ul of sample dilution in the first tube, and 500ul of sample dilution in the second to eighth tubes. Add 100 ul of 20 ng / ml standard solution to the first tube and mix it. Then aspirate 500 ul with the sampler and move to the second tube. Repeat the dilution in this manner repeatedly, draw 500ul from the seventh tube and discard it. The eighth tube is a blank control.

3. The 10 × specimen dilution is diluted 1:10 with distilled water (example: 1ml concentrated dilution + 9ml distilled water).

4. Washing solution: 1:20 dilution with redistilled water (example: 1ml concentrated washing solution is added with 19ml of redistilled water)

Testing procedures

1. Add sample: add 100ul of standard or sample to be tested to each well, mix the reaction plate thoroughly and place at 37 ℃ for 120 minutes.

2. Wash the plate: wash the reaction plate 4-6 times with the washing solution, and print it on the filter paper.

3. Add 100ul of the first antibody working solution to each well. The reaction plate was mixed thoroughly and then placed at 37 ° C for 60 minutes.

4. Wash board: same as above.

5. Add 100ul of enzyme-labeled antibody working solution to each well. Place the reaction plate at 37 ° C for 30 minutes.

6. Wash board: same as above.

7. Add 100ul of substrate working solution to each well, and place in a dark place at 37 ℃ for 15 minutes.

8. Add 100ul of stop solution to each well and mix well.

9. Measure absorbance at 450nm with a microplate reader within 30 minutes.

Result calculation and judgment

1. All OD values ​​should be calculated after subtracting the blank value.

2. With the standard products 2000, 1000, 500, 250, 125, 62.5, 31.2, 0 pg / ml as the abscissa, and the OD value as the ordinate, draw a graph on the graph paper and draw a standard curve.

3. Find the corresponding sIL-2R content on the graph according to the OD value of the sample, and then multiply it by the dilution factor.

Kit performance

1. Sensitivity: The minimum detection concentration of sIL-2R is less than 16pg / ml.

2. Specificity: simultaneous detection of recombinant or natural rat sIL-2R. Does not cross-react with other cytokines in rats.

3. Repeatability: The coefficient of variation within the board and the board is less than 12%.

Precautions

1. The above standard holes and samples to be tested are recommended to be re-holes, and the standard curve should be made at the same time for each measurement.

2. The washing process is critical. Insufficient washing will lead to an increase in accuracy error and OD value.

3. After opening the slats, the remaining slats should be sealed again to keep the slats dry.

4. This kit should be stored in a 4oC refrigerator.

5. This kit is for scientific research only, not for clinical diagnosis!

This goggles uses a high light transmission lens, which has the characteristics of anti-impact, anti-splash, anti-fog and light weight. In addition, it has two significant advantages, it is comfortable to wear, and the adjustable strap is suitable for various face shapes.

Material: Polycarbonate reinforced lens, anti-impact, anti-scratch, anti-fog, anti-splash, the frame is made of environmentally friendly, non-toxic and flexible polymer materials.

Feature: Soft and comfortable, close to the face, can be equipped with myopia glasses at the same time, breathable design, can be worn for a long time without fatigue, elastic lens strap, suitable for various face.

Safety Protective Multifunctional Goggles For Hospital

protective goggle, medical saftey goggles, reusable goggles safety, face mask with goggles, eye protection anti-fog goggles , medical face shield goggles

Shenzhen Chengxing Packing & Material Co.,Ltd , https://www.cxpack.com